Tag Archive for: hard water

Keeping Hot Water Flowing

Keeping hot water flowing is critical in the commercial sector, where domestic hot water (DHW) appliances will be subjected to extremely hostile conditions, with high temperatures, thermal stress and flue gas condensate on the combustion side and oxygen, minerals and chemical attacks leading to potential corrosion on the waterside. Given this harsh daily treatment, regular servicing and maintenance are key if business-critical service is to be observed. Ensuring consistent operations and prolonging the life of a commercial hot water and heating system should therefore be a key factor when specifying and costing out these business-critical systems.

Once an application is sized correctly and installed, that maintenance process begins with commissioning. This choice falls to the customer, but Adveco advises that it should be engaged to commission its own appliances. This ensures product warranty commences from the date of commissioning, rather than the date of delivery which may be months before a system eventually goes live. If not commissioned by Adveco, it will also fall to the customer to fault find, order the new part and return the faulty part, which can be a painful, time-consuming process for any facility manager who is already time-poor.

Keeping hot water flowing to support consistent operations, we specialise in both commissioning and proactive warranty service to the manufacturer’s recommendations. This is crucial for the consistent and efficient operation of an appliance which can be affected by a range of environmental factors, water condition most notably, but air quality can also harm operation. The UK is broadly split between hard and soft water conditions. In naturally soft water conditions, despite the use of sacrificial anodes, glass-lined vessels can rapidly succumb to critical corrosive damage, making stainless steel the optimal choice, with longevity countering higher purchase costs. Commercial glass-lined steel water heaters and tanks are usually the more cost-attractive proposition in the UK, especially in harder water areas, where, given the right conditions, they are generally resistant to attack from most chemicals and less-corrosive materials. However, the deposition of calcium carbonate, or scale, found in harder water remains a key issue, whether opting for glass-lined or stainless steel vessels.

The latest generation of water heaters may incorporate recirculation pumps to balance the flow of water through the appliance’s heat exchanger. That balance is critical as higher flows can reduce calcification, but it can also lead to corrosion where that flow is interrupted or broken. This is why internal forms should default to curves within the design to provide consistent, unbroken flows.

In typical operation in harder waters, in our experience, it is almost impossible to completely avoid the build-up of scale. Magnets simply do not work properly, so the use of an inhibitor fluid is critical alongside regular annual servicing. This can be of a representative number of appliances on a premise, with conditions that reduce or extend that service period. Low levels of scale may allow for units to be serviced in alternate years for example reducing costs. That annual service must however be thorough.

Too many times an ‘annual service’ will be a quick test with an analyser and issue of a landlord’s certificate. Such activity is relatively low cost, as it avoids the purchase of a service kit, but is ultimately a false economy. It will miss the early onset of calcification and means the water heater or boiler is more likely to suffer early, terminal blockage. For a thorough annual service, we would advocate appliances be fully drained, visually examined and any scale be removed. The process involves disassembly which requires the replacement of rubbers and gaskets, hence the requirement to purchase a service kit. Though more costly, such full services are substantially cheaper than the cost of replacing blocked heat exchangers, burners and even the entire appliance.

If scale build-up is not addressed, then within five years any descaler fluid introduced will simply wash over the surface, which will also easily resist the most concerted of hammer blows. At this stage, the descaler will also not pass through the heat exchanger, requiring its complete replacement. This is seen when servicing or preventative maintenance has been avoided or forgotten, at which point the manufacturer’s warranty will be void.

Annual monitoring of the inhibitor system used for boilers is also key, especially if heating facilities have been refurbished within a building. It is not uncommon to see boilers damaged after radiators are replaced, and new water introduced into the system without replacing lost inhibitor fluid. Monitoring and replacement as part of the annual service activity will again protect the heat exchangers.

The other key failure point is the burner in gas-fired appliances. Condensing boilers and water heaters will draw air from the plant room and if that is dusty, it will be sucked in, reducing the efficiency. If not cleaned regularly, the burner will soot up and eventually become blocked often requiring full replacement at some cost. Even if located in an open space, or exterior to the building the burner should be thoroughly inspected. Nearby building works can cause high levels of dust, and in dense urban areas, pollutants from vehicles can also be drawn into the appliance causing build-up of dirt on the burner.

Serviced thoroughly and regularly, commercial water heaters and boilers should have an efficient operational lifespan of at least ten years (depending on location), and we do see appliances still operating for twice that length of time. The caveat in these cases though is that the overall efficiency of legacy units operating for more than 10 years will be far lower than current generations of appliances and will almost certainly fail to meet current ERP regulations on emissions introduced in 2018 for new water heaters and boilers. So continued maintenance of such units would not only be a false economy in terms of running costs but will certainly not be contributing to any efforts to introduce better sustainability in a building.

In short, failure to descale, flush sediment, clean burners, check anodes or test for corrosion will reduce the operational longevity of any appliance, but also severely impact the efficient operation. That has negative implications on operational costs and unwarranted capital implications if there is a catastrophic failure. Under such conditions, this will almost certainly invalidate any manufacturer warranty that exists. Reactive service providers will only check gas pressures and overall condition, they will then wait for breakdowns and call outs.  Only by keeping hot water flowing through proactive servicing can you ensure any costly downtime of business-critical hot water is absolutely minimised.

Keeping hot water flowing. Visit our warranty service page or contact us to arrange for your service.

FUSION Commercial Hybrid Hot Water Systems from Adveco

  • FUSION is a complete range of low carbon hybrid heat pump and electric hot water systems
  • Resilient stainless steel water heating suitable for all UK regions
  • Compact design for new build and refurbishment projects seeking greater sustainability

Commercial hot water specialist Adveco, introduces the FUSION FPH-S range of low carbon, all-electric, packaged hybrid hot water systems. FUSION harnesses Adveco’s FPi32 Air Source Heat Pumps (ASHP), a high-pressure ATSH calorifier with electric immersion, controls, and metering to provide a reliable, high-temperature, sustainable and cost-effective system for new commercial build and refurbishment projects.

FUSION is available in 16 pre-specified variants with 6 or 10 kW preheat and 9 or 12 kW electric top-up, with capacities ranging from 200 to 500 litres all rated at 10 BAR for high-pressure applications. Able to meet a range of continuous capacity hot water demands from 257-377 litres/hour makes FUSION highly adaptable for a wide range of commercial buildings.

The FPi32 ASHP is specified to supply a working flow of 50°C for system preheat throughout the year, even when ambient air temperatures drop as low as -25°C. Electric immersion top-up then raises system temperatures in the calorifier to the necessary 60°C to meet commercial requirements for safe hot water demands. The stainless steel construction of the ATSH also makes it an excellent all-rounder, resistant to soft water corrosion and, with FUSION’s unique low electric immersion heat intensity (6W/cm²), is more resistant to scale build-up in hard water areas.

The physical design, dedicated controls and integrated metering ensure the ASHP preheat, and immersion work seamlessly to deliver the highest operational efficiencies. This enables FUSION to make the greatest gains possible from the heat pump, even when ambient temperature and system demands fluctuate. These gains offset much of the direct electrical energy usually required, delivering 53% carbon emissions saving and helping control the operational costs of providing business-critical hot water.

“For organisations with small to medium basin and sink led hot water demands and a desire to embrace a more sustainable business model, the FUSION FPH-S range provides a single, easy to accommodate, highly effective response,” says Bill Sinclair, technical director, Adveco. “By choosing one of these packaged hybrid water systems you gain optimum efficiencies, lower your carbon emissions and can be assured building regulations are being met for your commercial project.”

Fusion FPH-S Features

  • 16 pre-sized variants to meet a wide range of applications
  • 200, 300, 400 and 500-litre capacities
  • 6 or 10kW ASHP preheat
  • 9 or 12kW direct electric immersion heating
  • 257-377 litres/hour continuous capacity
  • 10 BAR high-quality AISI 316Ti and 316L stainless steel vessel (PED (97/23/EC), EN 12897)
  • Dedicated control system for simple operation and maintenance checks
  • Lower global warming potential with R32 ASHP
  • Compact space-saving form factor

Corrosion in Commercial Heating & Hot Water Systems: Part 2

Part 2 – Testing for Corrosion

If your premises are located in a soft water area then you need to be aware of the threats of corrosion to your system, and small leaks in your metal plumbing components could well be a sign of a more serious problem.

Testing water for corrosivity factors – pH, calcium concentration, hardness, dissolved solids content and temperature – as well as dissolved lead and copper due to corrosion is relatively straightforward.

Water hardness.The original accepted measurement of water corrosivity, the Langelier Saturation Index (LSI), was developed to determine whether a water source is potentially scale forming or scale dissolving (aggressive).  LSI, however, was not developed with the intention of testing naturally soft water, so relies on the chemical characteristics of the water, such as pH and especially hardness, to estimate the corrosivity. Positive values are indicative of non-corrosive water, negative LSI values indicate water could be corrosive.

The problem with LSI is that it based upon the oft-cited belief that calcium carbonate scale when deposited in a thin, carefully controlled, uniform layer can contribute to a protective barrier against corrosion. There is little scientific evidence to support this assumption

The highly variable physical and chemical conditions within a commercial hot water system mean it is very unlikely that a deposit of scale would ever be truly ‘uniform’. Deposition would typically be prevalent on the hottest elements of the boiler/water heater, and with the formation of crevices actually drive greater localised corrosivity in a fashion similar to pitting which would lead to the potential failure of an appliance. Additionally, as scale accumulates microscopic deposits of metal can be incorporated generating a ‘mini-galvanic’ effect.

Scale formation in a glass-lined indirect tank

Scale formation in a glass-lined indirect tank

Even without the issues of generating corrosion factors, it is never recommended that scale build-up be allowed in a hot water system. An increasing build-up of scale reduces the efficiency of an appliance by restricting the rate of flow and harming efficient transfer of heat. All of which drives up the operational costs.

For a more accurate prediction of calcium carbonate, and levels of corrosivity, the Ryznar Stability Index (RSI) was developed which considers pH, conductivity in TDS, calcium ions (CA²⁺), bicarbonate (HCO₃) and water temperature. An RSI of 6.0 -7.0 indicates water with little scale and the probability of some corrosion, with higher values being increasingly corrosive. Between 7.0 – 7.5, corrosion will be significant, becoming heavy between 7.5 and 9.0. Results above 9.0 are regarded as intolerable.

Both LSI and RSI are predicated on assessing the level of scale build-up, so an alternative approach is to test for metals concentrations, especially copper, which is achieved by drawing a sample to test directly from the commercial hot water system. Detection of iron, manganese or aluminium impurities in the water can also be indicative of corrosivity as localised deposits can also cause pitting in copper.

The only caveat is that the concentrations in open systems, such as where instantaneous water heaters are deployed, will quickly flush by-products of corrosion out of the system. So regular testing is soft water areas can be advantageous when seeking to prevent serious damage to appliances and associated system pipework.

UK water suppliers will typically provide self-assessment help for establishing local water quality, and can often provide details of most recent water tests based on a business’ postcode. Independent testing is also available, though there will be a cost associated. At Adveco our engineers can help and advise with your water assessment as part of the application sizing process.

Read Part 1 – Recognising the causes of corrosion

Read Part 3 – Preventing Corrosion: Glass versus Stainless Steel

Corrosion.

Corrosion in Commercial Heating and Hot Water Systems: Part 1

Part 1 – Recognising the Causes of Corrosion

Most metals will deteriorate or corrode, sometimes to a more stable chemical state through oxidation or reduction. This occurs over time when metals are in direct contact with any water, rusted iron being the most familiar, but it can also affect copper, lead, aluminium, zinc, and numerous other common metals. This becomes a real issue in water heating and distribution systems where metal appliances and pipes are continuously being attacked to the point of physical failure.

Corrosion in Commercial Heating and Hot Water Systems - Hard and soft water areas of the United Kingdom and IrelandCorrosion is a complex phenomenon, and no single dissolved substance is responsible for making water corrosive. There are several factors that can increase the likelihood of corrosion, especially the natural softness of water. When water passes through limestone and chalk in the ground, such as in the South East of the UK, it will pick up calcium and magnesium carbonates, when these minerals are greater than 280ppm the water is classed as hard. However, in Scotland, the North West and South West of England, and Western Wales, where water passes through hard igneous rock it lacks dissolved calcium and magnesium.  This makes the water naturally purer (less than 100 ppm). This soft water exhibits a low pH, low total dissolved solids (TDS) and negligible buffering capacity, all of which makes it more corrosive.

pH measures the hydrogen ion activity in a solution and is used to express the intensity of the acidity of a solution. Typically, the ideal pH for a commercial hot water system is slightly above 7 on the pH scale. Water with a low pH (below 7) is acidic, which is a problem as acids are compounds that release hydrogen ions which oxidize metal, accelerating corrosion. In general, the lower the pH, the more aggressive the corrosion.

There can be a range of reasons for the formation of anodic and cathodic sites, required to produce corrosion. Different materials used in the manufacture of the appliance or pipework, localised stresses, impurities and variances in the production of the metal, its composition and ‘grain size’ can all lead to surface imperfections. If localised variances are relatively small the anodic and cathodic sites will move around on the surface of the metal leading to a more uniform corrosion which is typically seen as surface oxidation or fouling.

Should the anodic sites be more static, localised corrosion can occur. This form of corrosion – which includes pitting, leaching and galvanic corrosion – is a more serious problem which can more rapidly lead to the failure of an appliance or pipework.

Pitting, one of the most destructive types of corrosion, occurs when there are large differences in surface conditions, leading the anodic and cathodic sites to become stationary. The process is exacerbated by low-velocity conditions, leading to the creation of a pit on the surface of the metal, the water inside becomes isolated and, over time, more corrosive as it produces an excess of positively charged metal cations, which attract chloride anions. In addition, hydrolysis produces hydrogen (H+) ions. The subsequent increase in acidity becomes self-sustaining as the concentration within the pit promotes even higher corrosion rates.

Leaching is the selective corrosion of a single element from the alloy. The most common occurrence in a building’s hot water system is the removal of zinc from brass (a copper-zinc alloy), a process also known as dezincification. Though the copper and zinc dissolve out simultaneously, the copper will precipitate back from the solution. The resultant copper alloy will change from a yellow brass to red colour and exhibit poor mechanical property. Common in cheaper valves and fittings where there is likely to be other ‘filler’ metals in the copper alloy, water containing sulphur, carbon dioxide, and oxygen, low pH conditions, low velocity and high free chlorine radicals drive especially aggressive corrosion causing fittings or valves that move to fracture and leak.
The complexity of commercial hot water systems, especially if the project is a refurbishment, can lead to two dissimilar metals (such as copper and stainless steel) coming into contact with each other and water. Under these conditions the corrosion rate of the more active (anodic) metal increases and the corrosion rate of the nobler (cathodic) metal decreases. This is Galvanic corrosion.

The galvanic scale - Recognising corrosion in commercial heating and hot water systems.When differing metals are connected in a hot water system, the water in contact with both metals acts as an electrolyte conducting the current. The current flows through the water from the positively charged less noble material to the negatively charged more noble material. Where the current leaves the less noble metal, corrosion will occur. As the current is usually greater close to the contact point of the two metals, this is where corrosion will be a greater issue. The higher the metal is on the Galvanic series, the nobler the metal will be, whilst the greater the distance between the two differing metals in the series, the greater the electrical potential will be and the greater the corrosion rate for the less noble metal.

Another major cause of corrosion found in commercial hot water systems is a direct result of oversizing or the failure to correctly balance water flow. An unfortunately common occurrence, oversizing a system not only raises the capital expenditure and the running costs of a hot water system, but the oversizing of the pumps leads to high-velocity hot water to circulate through the system. If there are any suspended solids in the water, they will be driven against the metal leading to erosional corrosion which is typified by smoothly grooved or rounded holes which mirror the directional or turbulent flow of the water. This erosion is most notable at points where water changes direction or is obstructed, leading to turbulence which further increases velocity and therefore the damage. If the high-velocity flow is not addressed quickly it can result in considerable damage, especially to the circulating pipework.

Certain chemicals (such as chlorine, chloramine and dissolved oxygen) can also make water more corrosive. The presence of oxidizing agents such as dissolved oxygen can cause metals to lose electrons and lead to corrosion. The removal of sulphate, or addition of chloride, the Chloride-to-sulphate mass ratio (CSMR) will accelerate corrosion in the presence of materials that contain lead, leaching it into the water. Sulphates inhibit corrosion by forming passive protective film layers and reducing galvanic currents between dissimilar metals, chlorides prevent the formation of such passive layers and stimulate galvanic current. Should the source water contain natural levels of chloride and treatment be installed to remove sulphate, the expectation is this would push the CSMR up and as a result, accelerate corrosion. The base 60°C requirement for commercial hot water can worsen such cases as high temperatures accelerate almost all chemical reactions. As temperatures hit 70°C, which is not uncommon in commercial systems the rate of corrosion will increase.

Read Part 2 – Testing for Corrosion